Haltbarer LED -LED -Beleuchtungstreiber 400 W 36V 11.1A Schaltnetzeversorgung
Produktbeschreibung
General: China enclosed switching power supply manufacturers, builtin type chassis, metal shell, switch power supply can be used for room temperature environment. Universal ac input voltage range,have complete protection function, 100% full load aging test.Security monitoring, display, light box, suitable for indoor use. Advantage: S-400W series compact single switching power supply feature: · Universal AC input range · Small volume,low weight,high efficiency · Protections: short circuit/over load · Cooling by free air convection · LED indicator for power on · 100% full load burn-in test |
Model |
S-400-5 |
S-400-12 |
S-400-15 |
S-400-24 |
s-400-48 | |
Output
|
DC voltage |
5V |
12V |
15V |
24V |
48v |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% | |
Rated current |
60A |
33A |
27A |
17A |
8.3A | |
Current range |
0~50A |
0~29A |
0~23.2A |
0~14.6A |
0~8.3A | |
Rated power |
250W |
348W |
348W |
350.4W |
398.4W | |
Ripple & noise |
100mvp-p |
150mvp-p |
150mvp-p |
150mvp-p |
200mvp-p | |
DC voltage adjustable range |
-9%~+ 10% |
±10% |
±10% |
±10% |
±10% | |
Input
|
Voltage range |
90~132VAC, /180~264VAC selected by switch, 235~370VDC |
||||
Frequency |
47~63HZ |
|||||
AC current |
6.5A/115VAC, 4.0A/230VAC |
|||||
Efficiency |
78% |
80% |
80% |
82% |
83% | |
Inrush current |
Cold start current 18A/115VAC 36A/230VAC |
|||||
Leakage current |
<3.5mA/240VAC |
|||||
Protection
|
Over load
|
105 ~ 135% rated output power |
||||
Protection type: fold back current liming, auto-recovery. |
||||||
Over voltage |
6.8~8.2v |
15.6v~17.8v | 18.6~20.8v | 30.6~33.2v | 54.8~56.6V | |
Protection type:Hiccup model,auto-recovery after solved the abnormal conditions | ||||||
Over tempreture | ≥55°c start fans, ≤55°c Stop fan, ≥85°C start over tempreture protection | |||||
Protection type:cut off output, auto-recovery | ||||||
Environment
|
Working temp, humidity |
-10°C~+60°C, 20%~90%RH |
||||
Storage temp, humidity |
-20°C~+85°C, 10%~95%RH non-condensing |
|||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
|||||
Safety
|
Withstand voltage |
I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC |
||||
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG: 100MΩ/500VDC |
|||||
Fit standard
|
Safety standard |
Compliance to UL1012 |
||||
EMC standard |
Compliance to EN55022,CLASS A |
|||||
Others
|
Dimension |
215*115*50mm(L*W*H) |
||||
Weight/packing |
1.0kg/20pcs/22kg |
Produktgruppe : Stromversorgung wechseln > S